Register
•
Search
•
FAQ
•
Memberlist
•
Usergroups
•
Galleries
•
Log in
Jetmen Revival downloads Forum Index
»
Jetmen Revival Downloads
Post a reply
Username
Subject
Message body
Emoticons
View more Emoticons
Font colour:
Default
Dark Red
Red
Orange
Brown
Yellow
Green
Olive
Cyan
Blue
Dark Blue
Indigo
Violet
White
Black
Font size:
Tiny
Small
Normal
Large
Huge
Close Tags
Add image to post
Options
HTML is
OFF
BBCode
is
ON
Smilies are
ON
Disable BBCode in this post
Disable Smilies in this post
Confirmation code: *
All times are GMT + 2 Hours
Jump to:
Select a forum
----------------
JETMEN ONLINE
Jetmen Revival
----------------
Jetmen Revival Downloads
Links
Graphics
Music
Other games
Topic review
Topic review
Author
Message
manj5sdckh
Posted: Fri 9:38, 18 Mar 2011
Post subject: http://www.airmaxclub.net/nike-air-max-lebron Nik
ustrial fan performance tables are based on standard air. Selecting a fan using standard tables will provide a fan capable of moving the required flow and developing the required pressure. As the temperature increases and humidity decreases, system resistance and the pressure developed by the fan will decrease at the same rate, and a constant flow rate is maintained. Altitude reduces the air pressure and density along with the amount of moisture the air can carry. The density and moisture values in table 1 must be divided by the correction factors in table 4 to determine the actual density and mois-ture content per cubic foot.
In many dryer applications, the static pressure requirement is between 0.5 and 3" 0f water column. For these pressure requirements, a duct vaneaxial fan often is the best selection. The duct vaneaxial fan offers a broad performance range and good pressure capability at high static efficiency. It also offers the benefit of placing the bearings
cheap Air Max 1
, shaft and drives on the negative pressure side of the propeller. This setup draws ambient air across those components during operation and discharges it into the hot moist air. This fan also can be provided with a shaft seal to further isolate the components or high temperature construction for operation up to 500 deg. F (260 deg C).
Divide density and moisture values by altitude correction factors to determine actual density and moisture.
For higher pressure ranges, a backward curved centrifugal fan often is selected. This design offers pressures up to 20" water gauge. They also offer the benefit of having the shaft and bearings outside the fan
http://www.airmaxclub.net/nike-air-max-lebron,
and they can be mounted on the roof with a weather cover.
As with all fan systems, it is important to remember that only available air can be exhausted. Fans cannot operate in a vacuum. If the exhausted air cannot be replaced in the facility, fan performance will drop off and production will suffer. The production facility must have makeup air for every cubic foot that is exhausted from the facility. The makeup air can be provided through general ventilation systems or as part of a heating, ventilating and air conditioning system.
With the exhaust requirements calculated and fan system sized to handle the required volume at the required pressure
Nike AirMax 1
, the drying process will run smoothly. Production results are consistent and the production facility's environment also is improved by removing contaminated air. A good understanding of exhaust requirements allows better control of the drying process.
Additional information can be found at the Industrial Pressure Blower Company web site .
Susanna Terlitskaia
Process Air Specialist
Industrial Pressure Blower Co.
/fan.html
/blower.html
fora.pl
- załóż własne forum dyskusyjne za darmo
Powered by
phpBB
© 2001, 2005 phpBB Group
Design by
Freestyle XL
/
Music Lyrics
.
Regulamin